Sell Zoomfashion 380VAC 3-Phase Under/Over Load Phase-Failure Over-Current Motor Protector Relay best price
5
2
ratings
1
sold
MYR 217.81
45% OFF
MYR 120.44
Ships from | Mainland China |
---|
Product Description
Welcome to our shop, our main business is home furnishing products.
✔High quality ✔High cost performance ✔Good after-sales service
➷Follow us and you will get a shopping voucher
➷When you place your order for the first time, you will receive a complimentary gift for free.
❤ The heart is not as good as action, pay attention to us.
Feature:
1. With overcurrent, phase failure, overload underload protection.
2. Multiple reset methods for various needs.
3. Digital intelligent motor protector, digital display, more convenient to observe motor status.
4. Fault record function, more intelligent and convenient.
5. Independent contact, a group of normally open, a group of normally closed.
Specification:
Item Type
Motor Protector
Protection Item
Operating conditions and setting range
Action time
Overload (definite time limit)
The running current exceeds the set value
0.5-60s
Setting range: 0.3-16A, 3-160A, 10-999A.
Overload (inverse time limit)
Operating current exceeds the set value
1-5 tripping curve inverse time limit
Setting range: 0.3-16, 3-160A, 10-999A
Underload
The operating current is lower than the set value. Put in after startup.
0.5-60s
The setting range is the same as the overload.
Note:
The underload value must be less than the overload value.
Phase failure
Current imbalance rate exceeds 50%
2s
Current imbalance
The current imbalance rate exceeds the set value. Setting range: 10-50%
5s
Unbalance rate = phase current - I average current maximum / I average current x 100%
Start delay
During the start-up of the motor, the protector will shield against overload, underload, locked-rotor, and unbalance protection.
Note:
A countdown will occur during the boot process.
0-200s
Locked-rotor
The running current exceeds the set overload factor and is put into operation after the start of the start.
3s
Setting range: 1.5-8 times overload current.
Short circuit
The operating current exceeds 10 times the set overload factor.
≤50MS
Leakage
The zero sequence current exceeds the set value. Setting range: 30ma-2.5A.
1S
A 5A/10mA zero-sequence current transformer must be connected.
Overvoltage
Operating voltage exceeds the set value, the return difference is 5%
5S
Setting range: 65-690V
Undervoltage
Operating voltage is lower than the set value, the difference is 5%
5S
Setting range: 65-600V
Package List:
1 x Motor Protector
1 x Instruction Manual
1 x Transformer
1 x Line
2 x Metal Accessories
#MotorProtector #MotorOverloadProtector #MotorUnderloadProtector #DigitalMotorProtector #IntelligentMotorProtector
Compare
MaiB 380VAC 3-Phase Under/Over Load Phase-Failure Over-Current Motor Protector Relay
5
2
ratings
3
sold
MYR 133.06
☊❐MaiB 380VAC 3-Phase Under/Over Load Phase-Failure Over-Current Motor Protector Relay
0
ratings
MYR 270.25
【Ready stock】✼MaiB 380VAC 3-Phase Under/Over Load Phase-Failure Over-Current Motor Protector Relay
0
ratings
MYR 254.58
【Ready stock】☽✶MaiB 380VAC 3-Phase Under/Over Load Phase-Failure Over-Current Motor Protector Relay
0
ratings
MYR 254.58
【Ready stock】▦♚MaiB 380VAC 3-Phase Under/Over Load Phase-Failure Over-Current Motor Protector Relay
0
ratings
MYR 287.12