Schneider LC1D09BD 24VDC TeSys D contactor - 3P(3 NO) - AC-3 - = 440 V 9 A - 24 V DC coil (1)
Schneider LC1D09BD 24VDC TeSys D contactor - 3P(3 NO) - AC-3 - = 440 V 9 A - 24 V DC coil (2)
Schneider LC1D09BD 24VDC TeSys D contactor - 3P(3 NO) - AC-3 - = 440 V 9 A - 24 V DC coil (3)
Schneider LC1D09BD 24VDC TeSys D contactor - 3P(3 NO) - AC-3 - = 440 V 9 A - 24 V DC coil (4)

Sell Schneider LC1D09BD 24VDC TeSys D contactor - 3P(3 NO) - AC-3 - = 440 V 9 A - 24 V DC coil best price

5
2
ratings
8
sold
MYR 165
Brand
Schneider Electric
Ships from
Selangor

Product Description

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V DC coil TeSys product name TeSys D product or component type Contactor device short name LC1D contactor application Motor control Resistive load utilisation category AC-4 AC-1 AC-3 poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC [Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit motor power kW 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) 4 kW at 380...400 V AC 50/60 Hz (AC-3) 4 kW at 415...440 V AC 50/60 Hz (AC-3) 5.5 kW at 500 V AC 50/60 Hz (AC-3) 5.5 kW at 660...690 V AC 50/60 Hz (AC-3) 2.2 kW at 400 V AC 50/60 Hz (AC-4) motor power HP (UL / CSA) 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors control circuit type DC standard [Uc] control circuit voltage 24 V DC auxiliary contact composition 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 overvoltage category III [Ith] conventional free air thermal current 25 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 105 A 40 °C - 10 s for power circuit 210 A 40 °C - 1 s for power circuit 30 A 40 °C - 10 min for power circuit 61 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit [Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified electrical durability 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V power dissipation per pole 1.56 W AC-1 0.2 W AC-3

From the same shop

Related items

You may also like