Sell Digital Temperature Humidity Controller Regulator Thermostat Hygrostat Thermometer Hygrometer Control with Humidity best price
5
6
ratings
4
sold
MYR 60
20% OFF
MYR 48
Brand | No Brand |
---|---|
Ships from | Mainland China |
Voltage | DC12V DC24V AC110-220V |
Product Description
Product Description
Control range:1%RH-99%RH
Load power:10A/AC220V
Measurement range:-20℃~80℃
Humidity range:1%RH-99%RH
Measurement error:±3%RH(environment temperature at 25℃)
Temperature precision:1℃ Humidity precision:1%RH
Display accuracy:1%RH
Power Supply:DC12V//220V(Choose)
Output type:10A relay output probe type
Temperature: NTC precision ±1℃
Humidity:resistance type sensor precision ±3℃
Dimension:90*60*26.5mm(L*W*H)
Temperature control object:one channel temperature(heating and refrigeration ventilator)
Or humidity(Dehumidify or humidify electrical appliance)
Probe line length:standard 1.5m
Permanent memory of parameter:set the all parameter with permanent memory
Power failure at the operation time:run after the power supply.
Working environment: temperature 0-55℃ humidity90%RH without condensation
Humidity control setting:Press Set keyboard one time,press three second enter into setting menu after humidity display flashing,it will display code HC.Press "▲ "keyboard or "▼"keyboard can cyclical selection HC-CP-PU-CA-HP parameter code.Please press Set keyboard if you need enter into a code,press "▲ "keyboard or "▼"keyboard to modify the required numerical for five seconds then return automatically.
Press "SET" keyboard twice enter into setting menu after temperature display flashing,and display code HC,press "▲ "keyboard or "▼"keyboard can cyclical selection HC-CP-PU-CA-HP
parameter code,please press "SET " keyboard if you need enter into one code ,press "▲ "keyboard or "▼"keyboard to modify the required numerical for five seconds then return automatically.
Dehumidification control: The way of mode control (code HC) it will be dehumidification control when setting as C.For example,set the humidity control value as 50% RH and humidity difference as 5%,relay start output,When environment humidity value ≤setting humidity value(50%RH),relay close output.
Damping control:The way of humidity control (code HC) ,set H as damping mode,for example,set the humidity control value as 50%RH and humidity difference as 5%RH. When temperature humidity value ≤setting value(50%RH)-difference/(5%RH) ,relay start output.when temperature humidity ≥setting value(50%RH),relay stop output.
HC:mode selection,H means humidifying mode,C means dehumidificatio mode.
D:return difference, start the humidify when in the humidifying mode=displaying humidity-return difference.start the humidify when in dehumidification mode=displaying humidity + return difference.
PU:Delay to start.when relay stop output and start timing.the interval time of next boot must greater than delay start time to avoid start frequently.
HP:Humidity upper limit alarm:when humidity exceed upper limit alarm,digital tube displaying "-H-",humidity lower than alarm setting value it will return back from alarm automatically.
LS;Humidity lower limit alarm:When humidity exceed lower limit,digital tube display"-L-",humidity higher than alarm setting value it will return back from alarm automatical