Features
Wide working input voltage from DC 5 to 36V, widely used in many device
Interface are clear and simple, and meet all your needs
Emergency "STOP" button
Reverse polarity protection, reverse polarity will not burn this module board
Sleep Mode - if this mode is enabled, screen will automatically turn off if without any operation for 5 minutes, any key will wake it up
Settable OP, CL, LOP, which are independent of each other and are automatically saved
After the module is powered down, all settings are memorized and will not lost
Optocoupler isolation, enhanced anti-jamming capability, industrial grade board
Specifications
Power Supply: 6 - 30V DC / Micro USB 5.0V DC
Trigger Source: Active-high (3.0 - 24V)
Output capability: DC 30VDC 5A or 220VAC 5A device
Standby Current: 20mA
Operating Current: 50mA
Life span: more than 10 million times
Working temperature: -40 to +85 ℃
Size: 6.2 * 3.8 * 1.7cm
Mode
P1: (Require an external trigger signal)
After trigger signal received, turn on the LOAD for OP time then turn off the LOAD and waiting for next signal to on again.
Below are the options while OP is operating:
P1.1: Signal being trigger again will not interrupt the OP
P1.2: Signal being trigger again start OP again
P1.3: Signal being trigger again reset the timer and waiting for trigger signal again; (Turn off the LOAD & stop timing)
P2: (Require an external trigger signal)
After trigger signal received, turn off the LOAD for CL time then turn on the LOAD for OP time and waiting for next signal to off again.
P3.1: (Require an external trigger signal)
After trigger signal received, turn on the LOAD for OP time then turn off the LOAD for CL time, this will continuous loop / cycle.
Once trigger signal received again LOAD will off and loop will stop.
Cycle times (LOP) can be pre-set.
P3.2: (No trigger signal require)
Autorun, turn on the LOAD for OP time then turn off the LOAD for CL time, this will continuous loop / cycle.
Cycle times (LOP) can be pre-set.
P4: (Require an external trigger signal)
After trigger signal received, turn on the LOAD then start time counter
Once no more trigger signal LOAD will off and counter will stop.
p.s “LOAD” is the device you are going to control to on / off
Time
0.1 second (minimum) ~ 999 minute (maximum) adjustable
Press STOP button to select the time frame by adjusting the decimal point
xxx. – Decimal point at the back, 1 – 999 second
xx.x – Decimal point at middle, 0.1 – 99.9 second
x.x.x – Decimal point all light up, 1 – 999 minute
How to set
The blinking Mode at the main menu is current mode (default is P1.1)
To select the Mode by press and hold SET key for 2 seconds and select interface mode by pressing UP / DOWN key to choose the Mode (P1.1 ~ P4) and press SET to confirm
After confirm the mode, it will need to set OP Time – Power on time (Closed circuit), UP / DOWN to choose, SET to confirm